Jotul F 500 Manuale Utente

Navigare online o scaricare Manuale Utente per Stufe Jotul F 500. Jotul F 500 User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 20
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
....................................
Installation and Operating Instructions for USA
Installation et fonctionnement pour Canada
Safety notice: If this solid fuel room heater is not properly installed, a house fire may result. For
your safety, follow the installation directions. Contact local building or fire officials about restrictions
and installation inspection requirements in your area. Kindly save these instructions for future
reference.
Avis de sécurité: Une installation non appropriée de ce poêle de chauffage risque de provoquer un
incendie. Assurez votre sécurité en respectant les directives dinstallation suivantes. Consultez les
autorités locales du bâtiment ou de la prévention des incendies au sujet des restrictions et exigences
relatives aux inspections dinstallations dans votre région.
Tested and listed by ITS Intertek Testing Services, Middleton, Wisconsin.
Tested to U.S. Standards: ANSI/UL 1482, Canadian Standards: CAN/ULC-S627-M93
....................
Jotul F 500
Oslo Woodstove
Vedere la pagina 0
1 2 3 4 5 6 ... 19 20

Sommario

Pagina 1 - Oslo Woodstove

...Installation and Operating Instructions for USAInstallation et fonctionnement pour CanadaSafety notice: If this s

Pagina 2 - 28 1/4

NOTICEAccessories for woodstoves for clearance reduction havebeen developed by many manufacturers. If not followingthe methods of the inst

Pagina 3

OSLO F500 WOODSTOVE CLEARANCESUNPROTECTED SURFACEPARALLEL TO THE WALLPROTECTED WALL (PER NFPA 211)PARALLEL TO THE WALLUNPROTECTED SURFACECORNER

Pagina 4 - INSTALLATION

UNPROTECTED SURFACE PROTECTED SURFACE NFPA 211STOVE CLEARANCES PARALLEL INSTALLATION PARALLEL INSTALLATIONSIDE REAR CORNER* SIDE REAR CORNER*Stove-no

Pagina 5 - Prefabricated Chimneys

WARNING:DO NOT INSTALL IN A BEDROOM/SLEEPINGROOM. THE STRUCTURAL INTEGRITY OF THEMOBILE HOMES FLOOR, WALL, CEILING/ROOFMUST BE MAINTAINED.OPERATIO

Pagina 6 - FIGURE 2

Starting and Maintaining a FireBurn only solid wood directly on the bottomgrate of the stove, do not elevate the fire in anyway.The ash pan door on th

Pagina 7 - FIGURE 4

MAINTENANCEAsh remomal: OF COURSE, FOR YOURPROTECTION ALWAYS WEAR SAFETYGLOVES WHEN HANDLING THE ASH PAN.Ash removal will be required periodi

Pagina 8 - FIGURE 5

General MaintenanceLike your car, regular maintenance prolongs the lifeof your appliance. The following procedures do nottake long and are generally

Pagina 9 - FIGURE 8

Outside air may be required if: 1. The OSLO F500 does not draw steadily,smoke rollout occurs, fuel burns poorly, or back-drafts occur whether

Pagina 10 - FIGURE 10

EXPLODED VIEW OF THE OSLO F500ONLY USE REPLACEMENTS PARTS PROVIDED THROUGH YOUR AUTHORIZED JØTUL DEALER.1819181714161520222324212526272829343031333229

Pagina 11 - (PER NFPA 211)

ALTERNATE FLOOR PROTECTIONAll floor protection materials must be non-combustible ie. metal,brick, stone, mineral fiber boards). Any combustible

Pagina 12

TABLE OF CONTENTS:Standards and Safety Notices...3Installations...4Chimney Requirem

Pagina 13

Stoves and fireplaces must be installed to conform to local and national building regulations. Before preparing for the installation ofthe appl

Pagina 14 - THERMOMETER

STANDARDSThe OSLO F500 wood stove has been tested andlisted to;U.S. Standards: ANSI/UL 737 and ANSI/UL 1482.Canadian Standards: CAN/ULC-S627-M93Tests

Pagina 15 - See figure 13

INSTALLATIONIF THIS SOLID FUEL ROOM HEATER IS NOTPROPERLY INSTALLED A HOUSE FIRE MAYRESULT. FOR YOUR SAFETY, FOLLOW THEINSTALLATION DIRECTIONS. CON

Pagina 16 - LD/SA 4'

Prefabricated ChimneysIf a prefabricated metal chimney is to be used itmust be a chimney type that is tested and listed foruse with solid fuel burning

Pagina 17

WALL PASS-THROUGHSWhen your installation unavoidably requires thechimney connector to pass through a combustible wallto reach the chimney, always cons

Pagina 18 - AUTHORIZED JØTUL DEALER

In CanadaThe Canada the standard has been established by theCanadian Standard Association. The installation mustconform to CAN/CSA-B365, Installation

Pagina 19 - PARTS LIST FOR THE OSLO F500

Hearth-mount into a Masonry FireplaceThe OSLO F500 may be installed into a masonryfireplace provided the height of the opening is aminimum of 29.

Pagina 20 - Jøtul North America

CLEARANCES TO COMBUSTIBLESFloor ProtectionFloor protection under the stove, must be constructedof a non-combustible material for protection fromradia